Print Report | Back to Sample Detail

Sample Record for 2020-03-24-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214421 DEA: 01362704 EFIS: 0116000031 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-1-62.2/R78.9
Work Description: HOT MIX ASPHALT OVERLAY.
Location Description: MENDOCINO COUNTY NEAR FORT BRAGG FROM 0.1 MILE NORTH OF PUDDING CREEK BRIDGE TO 0.6 MILE NORTH OF WAGES CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 1324 South State Street, Ukiah, CA 95482
Resident Engineer: Roozbeh Hadipour Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-24-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/24/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/10/2020
The quantity of what the sample constitutes: 200
A brief description of the sample: ASTM A193 HDG Anchor Rod
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BMSI

Material Information

Rocap Number(s): N/A
Heat Number(s): 10610630
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A193 B7
Bolt Length(s): 12"
Nut Specification: N/A
Washer Specification: N/A
Finish: ASTM A153
Diameter/Size: 5/8" DIAMETER
Bolt Mfg. Lot Number: N/A
Rocap Test Requirement(s): no
Lubricant Requirements(s):

Test Results

Test 1 of 18

DIME Test ID: 2020-03-24-4-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1AUNC 5/8 0.2263139113913888512861929068A193 Rod
UTM 400kip
Temperature 72

Test 2 of 18

DIME Test ID: 2020-03-24-4-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1BUNC 5/8 0.2263138713913886512803128935A193 Rod
UTM 400kip
Temperature 72

Test 3 of 18

DIME Test ID: 2020-03-24-4-3
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1CUNC 5/8 0.2263128813913840512926229213A193 Rod
UTM 400kip
Temperature 72

Test 4 of 18

DIME Test ID: 2020-03-24-4-4
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1DUNC 5/8 0.2263104513813731611986827090A193 Rod
UTM 400kip
Temperature 72

Test 5 of 18

DIME Test ID: 2020-03-24-4-5
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
5EUNC 5/8 0.2263167414014014613063529523A193 Rod
UTM 400kip
Temperature 72

Test 6 of 18

DIME Test ID: 2020-03-24-4-6
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1FUNC 5/8 0.2263116013813780612772928867A193 Rod
UTM 400kip
Temperature 72

Test 7 of 18

DIME Test ID: 2020-03-24-4-7
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1GUNC 5/8 0.2263152314013947313034729459A193 Rod
UTM 400kip
Temperature 72

Test 8 of 18

DIME Test ID: 2020-03-24-4-8
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1HUNC 5/8 0.2263141813913901712959829289A193 Rod
UTM 400kip
Temperature 72

Test 9 of 18

DIME Test ID: 2020-03-24-4-9
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1IUNC 5/8 0.2263167114014013013036329462A193 Rod
UTM 400kip
Temperature 72

Test 10 of 18

DIME Test ID: 2020-03-24-4-10
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .577 in
Pitch Diameter 2nd no data in

Test 11 of 18

DIME Test ID: 2020-03-24-4-11
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .578 in
Pitch Diameter 2nd no data in

Test 12 of 18

DIME Test ID: 2020-03-24-4-12
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .571 in
Pitch Diameter 2nd no data in

Test 13 of 18

DIME Test ID: 2020-03-24-4-13
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .571 in
Pitch Diameter 2nd no data in

Test 14 of 18

DIME Test ID: 2020-03-24-4-14
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .572 in
Pitch Diameter 2nd no data in

Test 15 of 18

DIME Test ID: 2020-03-24-4-15
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1F
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .572 in
Pitch Diameter 2nd no data in

Test 16 of 18

DIME Test ID: 2020-03-24-4-16
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1G
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .573 in
Pitch Diameter 2nd no data in

Test 17 of 18

DIME Test ID: 2020-03-24-4-17
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1H
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .571 in
Pitch Diameter 2nd no data in

Test 18 of 18

DIME Test ID: 2020-03-24-4-18
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1I
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .569 in
Pitch Diameter 2nd no data in