Print Report | Back to Sample Detail

Sample Record for 2020-03-11-29

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214878 DEA: 020H5404 EFIS: 0215000049 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-30.4/T57.9
Work Description: DRAINAGE REHABILITATION IN TRINITY COUNTY
Location Description: VARIOUS LOCATIONS FROM 0.5 MILE SOUTH OF TRINITY RIVER BRIDGE TO 1.6 MILES NORTH OF BOWERMAN RIDGE ROAD.
Contractor Name: R. BROWN CONSTRUCTION COMPANY INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-11-29
TL Number from the TL Form: 847762
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Preliminary
Type of Material: Soil
Sample Taken Date: 03/11/2020
Date that the sample was received by the laboratory/organization performing the testing: 03/16/2020
The quantity of what the sample constitutes: Culvert Recommendation
A brief description of the sample: Soil
From where was the sample collected: Source
Laboratory sample identification: D78345
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: In Situ

Material Information

The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: 02-TRI-3-38.23, at DI, 6 inch Depth
Where the material sample would have been placed if not sampled: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2020-03-11-29-1
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Verified Date: 04/03/2020
Date Tested: 03/23/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 7127.88 Ohms
Minimum soil resistivity at 15.5 7128 Ohm-cm
Minimum soil resistance of the lab measurement 6350 Ohms
Soil sample temperature 20.4 C
pH of soil 6.13