Print Report | Back to Test Summary

Testing Report for 2020-03-26-6-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK-CHEM
EFIS: STOCK-CHEM
Project ID: 77777
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-26-6
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 3/26/2020
Date that the sample was received by the laboratory/organization performing the testing: 4/2/2020
The quantity of what the sample constitutes: 148
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AM Nut and Bolt

Material Information

Rocap Number(s): N/A
Heat Number(s): 58035126
Nut Mfg. Lot Number(s): 31662-6215104903
Washer Mfg. Lot Number(s): 318139
Bolt Specification: F1554
Bolt Length(s): 15"
Nut Specification: A194
Washer Specification: F436
Finish: Galvanized
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 58035126
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2020-03-26-6-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 4/3/2020
Verified Date: 4/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A194 Nut
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1 31662-6215104903 58823 A194 Nut fsaylor
UTM: 400kip
Temperature: 72 f