Print Report | Back to Sample Detail

Sample Record for 2020-03-25-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214680 DEA: 030F2854 EFIS: 0319000205 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99-7.1/9.4
Work Description: Construct the temporary bridge superstructures, adjacent paving and pave temporary alignment
Location Description:
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4001 Bradshaw Road, Sacramento, CA 95827
Resident Engineer: Masoud Saed Structure Rep.: Chau Ha

Sample Information

DIME Sample ID: 2020-03-25-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 03/25/2020
Date that the sample was received by the laboratory/organization performing the testing: 03/27/2020
The quantity of what the sample constitutes: 2 bars 4 nuts
A brief description of the sample: 1-3/8" Threaded Bar w/ nuts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size:
Nut Specification for Threaded Bar: N/A
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 6214955103
Nut Heat Number(s): 71079534, 72076635
Bar Lot Number: Unknown
Nut Lot Number: Unknown
Coupler Heat Number(s): Unknown
Coupler Grade: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2020-03-25-2-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Threaded Bar and Nut. Nut Heat 72076635
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
1ASTM A722 Type II Deformed Bar 1 3/8 : 36mm11.356157293.70143.88034.6A722 Threaded Bar and Nut. Nut Heat 72076635bewing
Temperature 72 f
UTM 2000kip

Test 2 of 2

DIME Test ID: 2020-03-25-2-2
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Threaded Bar and Nut. Nut Hreat 71079534
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
1ASTM A722 Type II Deformed Bar 1 3/8 : 36mm11.58161430.10145.138.18100A722 Threaded Bar and Nut. Nut Hreat 71079534bewing
Temperature 72 f
UTM 2000kip