Print Report | Back to Test Summary

Testing Report for 2020-03-20-1-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024G5004
EFIS: 0214000031
Project ID: 212657
QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-299-1.9-2.3
Work Description: VIADUCT WIDENING
Location Description: TRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mandhir Grewal
Structure Rep.: Michael Mccracken

Sample Information

DIME Sample ID: 2020-03-20-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 3/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 3/27/2020
The quantity of what the sample constitutes: 20
A brief description of the sample: #10 Button Heads
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Camblin Steel

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 9000755
Head Manufacturer Lot Number(s): A182386
Rebar Size: 10
Headed Bar Model Name: BNX Buttonhead
Size of Head: Full Size - 9x
Head Connection Type: Crimped Head
Head Shape: Circular
Rebar Manufacturer: CMC Rancho Cucamonga
Head Manufacturer: Barsplice
Head Fabricator: Barsplice
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2020-03-20-1-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 3/27/2020
Verified Date: 3/27/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
1 1.27 123421 97182 OK Necking fsaylor
Temperature: 72 f
UTM: 400kip