Print Report | Back to Test Summary

Testing Report for 2020-03-06-8-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK-CHEM
EFIS: STOCK-CHEM
Project ID: 77777
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-06-8
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 3/6/2020
Date that the sample was received by the laboratory/organization performing the testing: 3/23/2020
The quantity of what the sample constitutes: 226
A brief description of the sample: 3/4" x 30" Anchor Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AM Nut and Bolt

Material Information

Rocap Number(s):
Heat Number(s): 58038169-05
Nut Mfg. Lot Number(s): 31662-6215104903
Washer Mfg. Lot Number(s): 017297
Bolt Specification: F1554 GR 55
Bolt Length(s): 30"
Nut Specification: A194 2H
Washer Specification: F436
Finish: HDG
Diameter/Size: 3/4" x 30"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2020-03-06-8-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 3/26/2020
Verified Date: 4/1/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1B 31662-6215104903 58640 Nut Proof Load spaine
UTM: 400kip
Temperature: 72 f