Print Report | Back to Test Summary

Testing Report for 2020-01-28-6-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 072159U4
EFIS: 0715000160
Project ID: 211260
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work Description: CONSTRUCT HOV LANES AND MIX FLOW LANES.
Location Description: LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: George Saker
Structure Rep.: Danny Lalonde

Sample Information

DIME Sample ID: 2020-01-28-6
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 1/28/2020
Date that the sample was received by the laboratory/organization performing the testing: 1/30/2020
The quantity of what the sample constitutes: PSUE 4 Bags
A brief description of the sample: 3/4 HMA-A-SP R21
From where was the sample collected: Manufacturer
Laboratory sample identification: 0121A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Irwindale

Material Information

Source Identification (SMARA or name of Pit): 91-19-0035
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A-SP R21
The fabricator/manufacturer designation for the sample: 220817A IRW SJR
The plant number: Unknown
A detailed description of where the material sample was collected: Belt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2020-01-28-6-9
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Date Tested: 2/3/2020
Verified Date: 3/17/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: RAP Gradation After Ignition Oven
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 99 %
Cumulative percent passing the #4 sieve: 79 %
Cumulative percent passing the #8 sieve: 60 %
Cumulative percent passing the #16 sieve: 46 %
Cumulative percent passing the #30 sieve: 35 %
Cumulative percent passing the #50 sieve: 24 %
Cumulative percent passing the #100 sieve: 16 %
Cumulative percent passing the #200 sieve: 11 %