Print Report | Back to Sample Detail

Sample Record for 2020-01-30-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214653 DEA: 050K3304 EFIS: 0512000068 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-45.5/45.5
Work Description: Gaviota Culvert Replacement
Location Description: On Rte 101 in Santa Barbara County, near Gaviota State Park and just South of Gaviota Safety Roadside Rest Area
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-01-30-14
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 01/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/30/2020
The quantity of what the sample constitutes: One Culvert
A brief description of the sample: Native Soil
From where was the sample collected: Job Site
Laboratory sample identification: 20-D-007
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Existing

Material Information

The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Unknown
Where the material sample would have been placed if not sampled: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2020-01-30-14-1
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Verified Date: 01/31/2020
Date Tested: 01/31/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 2230 Ohms
Minimum soil resistivity at 15.5 2230 Ohm-cm
Minimum soil resistance of the lab measurement 2000 Ohms
Soil sample temperature 20.1 C
pH of soil 7.25