Print Report | Back to Test Summary

Testing Report for 2020-01-23-7-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-01-23-7
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 1/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 1/27/2020
The quantity of what the sample constitutes: 172
A brief description of the sample: .75"-10 x 15" DES assemblies
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: A and M Nut and Bolt

Material Information

Rocap Number(s):
Heat Number(s): Bolt 5803981306 Nut 6215104903 Washer 189092
Nut Mfg. Lot Number(s): 31662-6215104903
Washer Mfg. Lot Number(s): 317370
Bolt Specification: A1554-15 Gr 55
Bolt Length(s): 15"
Nut Specification: A194
Washer Specification: A436
Finish: HDG
Diameter/Size: .75"
Bolt Mfg. Lot Number: 48601-PPO
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2020-01-23-7-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 1/28/2020
Verified Date: 2/3/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
1 58039813-06 0.499 0.196 76293 95463 24.9 spaine
UTM: 67kip
Temperature: 72 f