Print Report | Back to Test Summary

Testing Report for 2020-01-16-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07138204
EFIS: 0700000142
Project ID: 3825
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47,103-3.5/4.6,0.0/1.1
Work Description: REPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location Description: LOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Daniel Leon
Structure Rep.: Andy Chen

Sample Information

DIME Sample ID: 2020-01-16-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 1/16/2020
Date that the sample was received by the laboratory/organization performing the testing: 1/20/2020
The quantity of what the sample constitutes: 6
A brief description of the sample: 1 1/4"-7 x 5" MD fastener assemblies
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: St Louis Screw and Bolt

Material Information

Rocap Number(s):
Heat Number(s): Bolt 20372110 Nut 6214785804
Nut Mfg. Lot Number(s): 29738
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A325
Bolt Length(s): 5"
Nut Specification: ASTM A563 DH
Washer Specification: N/A
Finish: MG
Diameter/Size: 1 1/4"
Bolt Mfg. Lot Number: BM0281
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2020-01-16-1-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Date Tested: 1/22/2020
Verified Date: 1/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Bolt Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Wedge Angle (deg) Comments Tested By
1A BM0281 1.2500 121476 540.35 6.00 A325 Wedge Tensile spaine
UTM: 450kip
Temperature: no data