Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213943 DEA: 051G5704 EFIS: 0515000049
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-58-0.7/1.9
Work Description: COLD PLANE AC, PLACE RHMA-G AND RECONSTRUCT CURB RAMPS.
Location Description: SAN LUIS OBISPO COUNTY AT SANTA MARGARITA FROM 0.7 MILE EAST OF ROUTE 101/58 SEPARATION TO J STREET
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Road, Santa Barbara, CA 93111
Resident Engineer: Hassan Iman Structure Rep.: Unknown
DIME Sample ID: 2020-01-01-7
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Quality Control
Type of Material: Asphalt Modifier
Sample Taken Date: 01/01/2020
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 0
A brief description of the sample: Modifier
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tricor
DIME Test ID: 2020-01-01-7-1
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Kinematic Viscosity
|
24.0000 mm2/s
|
Second Kinematic Viscosity
|
24.0000 mm2/s
|
Kinematic Viscosity
|
24.0000 mm2/s
|
Dynamic Viscosity
|
24.0000 mPa-s
|
DIME Test ID: 2020-01-01-7-2
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
SI Units
|
Ambient Barometric Pressure unit?
|
kPa
|
Corrected Flash Point
|
216 C
|
DIME Test ID: 2020-01-01-7-3
Test Method: ASTM D2007-11: Standard Test Method for Characteristic Groups in Rubber Extender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method (Clay Gel Absorption)
Verified Date: 01/17/2020
Date Tested: 01/01/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method of determination of aromatic content:
|
Difference
|
Asphaltenes, percent by mass
|
0.0 %
|
Aromatics, percent by mass
|
65.0 %
|