Print Report | Back to Sample Detail

Sample Record for 2019-02-22-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-02-22-15
TL Number from the TL Form: C955245
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 02/22/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/22/2019
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 1/2" Virgin Aggregate
From where was the sample collected: Source
Laboratory sample identification: 19-J-002
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sierra Pacific - Avenal

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-10-0006
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Source
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 8

DIME Test ID: 2019-02-22-15-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Percentage of questionable, coarse, 2 faced particles tested 0 %
Percentage of questionable, coarse, 1 faced particles tested 0 %
Percentage of questionable, fine, 1 faced particles tested 0 %
Percentage of fractured, coarse, 2 faced particles tested 99 %
Percentage of fractured, coarse, 1 faced particles tested 100 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 2 of 8

DIME Test ID: 2019-02-22-15-2
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation C
Mass of sample on No.12 sieve (after 500 revolutions) 4073 grams
Percent loss after 100 revolutions 4 %
Percent loss after 500 revolutions 19 %

Test 3 of 8

DIME Test ID: 2019-02-22-15-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 89

Test 4 of 8

DIME Test ID: 2019-02-22-15-4
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method A
Determination By Mass
Dimensional ratio used 1:5
Weighted percentage of particles (by mass) that were flat 0 %
Weighted percentage of particles (by mass) that were elongated 0 %
Weighted percentage of particles (by mass) that were both flat and elongated 1 %
Weighted percentage of particles (by mass) that were neither flat nor elongated 99 %

Test 5 of 8

DIME Test ID: 2019-02-22-15-5
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Plastic Index(PI) NP
Liquid Limit (LL) 0 %
Plastic Limit (PL) 0 %

Test 6 of 8

DIME Test ID: 2019-02-22-15-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.587
Absorption 1.9 %

Test 7 of 8

DIME Test ID: 2019-02-22-15-7
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.531
Bulk specific gravity (SSD Basis) 2.603
Apparent specific gravity 2.726
Absorption 2.8 %

Test 8 of 8

DIME Test ID: 2019-02-22-15-8
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 12/31/2019
Date Tested: 02/22/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Which test procedure(s) is/are used? Procedure A and Procedure B
Was strict temperature control maintained? Yes
What type of water was used? Distilled
Durability Index (coarse) 74
Durability Index (fine) 78