Print Report | Back to Test Summary

Testing Report for 2019-12-11-14-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024F7804
EFIS: 0213000032
Project ID: 212794
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA,LAS,PLU,SHA,SIS,TRI-5-22087-25.7
Work Description: CMS SIGNS IN SHASTA COUNTY
Location Description: IN BUTTE, LASSEN, PLUMAS, SHASTA, SISKIYOU AND TRINITY COUNTIES IN VARIOUS LOCATIONS.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Joel Gasik
Structure Rep.: Nicholas McLean

Sample Information

DIME Sample ID: 2019-12-11-14
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/11/2019
Date that the sample was received by the laboratory/organization performing the testing: 12/18/2019
The quantity of what the sample constitutes: 462
A brief description of the sample: 3/4-10 GR DH HV MG NUT w/ blue dye
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Structural and Steel Products

Material Information

Rocap Number(s):
Heat Number(s): 100893710
Nut Mfg. Lot Number(s): 414755A
Washer Mfg. Lot Number(s):
Bolt Specification: n/a
Bolt Length(s): Unknown
Nut Specification: n/a
Washer Specification: n/a
Finish: Mechanically Galvanized to ASTM B695
Diameter/Size: 3/4"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s): not required. snug tight

Test Information

DIME Test ID: 2019-12-11-14-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 12/20/2019
Verified Date: 12/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1B 414755A 59442 Nut Proof Load spaine
UTM: 450kip
Temperature: 72 f