Print Report | Back to Test Summary

Testing Report for 2019-11-27-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 072159U4
EFIS: 0715000160
Project ID: 211260
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work Description: CONSTRUCT HOV LANES AND MIX FLOW LANES.
Location Description: LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: George Saker
Structure Rep.: Danny Lalonde

Sample Information

DIME Sample ID: 2019-11-27-2
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 11/27/2019
Date that the sample was received by the laboratory/organization performing the testing: 12/10/2019
The quantity of what the sample constitutes: 4
A brief description of the sample: #5 A706 Grade 60 bar with #5 Button Head
From where was the sample collected: Fabricator
Laboratory sample identification: Lot 6
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Integrity Rebar Placers

Material Information

Production or Authorization Testing: Authorization Testing
Rebar Heat Number(s): 65032736
Head Manufacturer Lot Number(s): A190690
Rebar Size: 5
Headed Bar Model Name: BNX Buttonhead
Size of Head: Reduced Size - 4x
Head Connection Type: Crimped Head
Head Shape: Circular
Rebar Manufacturer: CMC Commercial Metals
Head Manufacturer: Bar Splice
Head Fabricator: Integrity Rebar Placers
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2019-11-27-2-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 12/11/2019
Verified Date: 12/11/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
6 0.31 32601 105164 Ok Necking fsaylor
Temperature: 72 f
UTM: 400kip