Print Report | Back to Test Summary

Testing Report for 2014-08-13-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 041706U4
EFIS: 0400000450
Project ID: 1841
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-880-30.0/ 31.0
Work Description: 5th Avenue Overhead Bridge Replacement
Location Description: 5th Ave and 880. Â
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ta Seng
Structure Rep.: Art Pannu

Sample Information

DIME Sample ID: 2014-08-13-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 8/13/2014
Date that the sample was received by the laboratory/organization performing the testing: 8/20/2014
The quantity of what the sample constitutes: 2
A brief description of the sample: concrete cylinders
From where was the sample collected: Other
Laboratory sample identification: CL140993
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA

Material Information

The concrete mix design number: D20PP5E1
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Job site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2014-08-13-2-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 9/24/2014
Capped in accordance with: ASTM C617/CTM521
Verified Date: 9/24/2014
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Capped in accordance with?: ASTM C617/CTM521
Compressive strength (to nearest 10 psi): 5170 psi
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.01 in
Compressive strength of cylinder 1: 5084.8 psi
Compressive strength of cylinder 2: 5254.5 psi
Maximum load on cylinder 1: 144714 lb
Maximum load on cylinder 2: 149071 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 42 days