Print Report | Back to Sample Detail

Sample Record for 2014-09-17-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209175 DEA: 030F2204 EFIS: 0300000072 QA Service Level: 1
DIST-CO-RTE-PM: 03-ED-50-R30.7/R31.7
Work Description: REPLACE BRIDGE.
Location Description: SLY PARK UNDERCROSSING
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: P.O. Box 1508 , Rancho Cordova, CA 95741
Resident Engineer: Jarrett Woodruff Structure Rep.: Brandon Miller

Sample Information

DIME Sample ID: 2014-09-17-5
TL Number from the TL Form:
Sample Submitted By Organization: Viking Construction Company, Incorporated - Rancho Cordova
Sample Organization Contact: (916) 852-5530
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 09/17/2014
Date that the sample was received by the laboratory/organization performing the testing: 09/17/2014
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: Stage 2 Abutment 1
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Folsom Ready Mix

Material Information

Source Identification (SMARA, name of Pit or Job Site): Stage 2 Abutment 1
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Folsom Ready Mix Stockpile
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size:
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2014-09-17-5-1
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 09/22/2014
Date Tested: 09/17/2014
Submitted By Organization: Viking Construction Company, Incorporated - Rancho Cordova
Organization Address: 11315 Sunrise Gold Circle, Suite A,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: dfishback@vikingbridges.com
Organization Phone: (916) 852-5530
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? 1 in. x No. 4 - Coarse Aggregate
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 98 %
Cumulative percent passing the 3/4 in. sieve 77 %
Cumulative percent passing the 1/2 in. sieve 33 %
Cumulative percent passing the 3/8 in. sieve 12 %
Cumulative percent passing the #4 sieve 2 %
Cumulative percent passing the #8 sieve 2 %

Test 2 of 2

DIME Test ID: 2014-09-17-5-2
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 09/22/2014
Date Tested: 09/17/2014
Submitted By Organization: Viking Construction Company, Incorporated - Rancho Cordova
Organization Address: 11315 Sunrise Gold Circle, Suite A,
Organization City: Rancho Cordova
Organization State: CA
Organization Zipcode: 95742
Organization Email: dfishback@vikingbridges.com
Organization Phone: (916) 852-5530
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Fine Aggregate
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 99 %
Cumulative percent passing the #8 sieve 84 %
Cumulative percent passing the #16 sieve 68 %
Cumulative percent passing the #30 sieve 38 %
Cumulative percent passing the #50 sieve 13 %
Cumulative percent passing the #100 sieve 5 %
Cumulative percent passing the #200 sieve 2.9 %