Print Report | Back to Sample Detail

Sample Record for 2019-09-20-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-09-20-6
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 09/20/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/24/2019
The quantity of what the sample constitutes: 72
A brief description of the sample: Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s):
Number of Coils: Unknown
Group Number: 10928
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0542118-2,S0597619, S0592219,S0539219, S0597719
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Results

Test 1 of 10

DIME Test ID: 2019-09-20-6-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0542118-2S378813-10.226015556818.328.21.62bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 2 of 10

DIME Test ID: 2019-09-20-6-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0542118-2S378813-40.226041156755.927.91.6bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 3 of 10

DIME Test ID: 2019-09-20-6-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597619S335047-30.2186010856385.629.61.81bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 4 of 10

DIME Test ID: 2019-09-20-6-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597619S378816-20.2186019453840.222.91.77bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 5 of 10

DIME Test ID: 2019-09-20-6-5
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0592219S335048-50.2186019157052.8291.77bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 6 of 10

DIME Test ID: 2019-09-20-6-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0592219S335049-40.2186044856058.728.91.89bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 7 of 10

DIME Test ID: 2019-09-20-6-7
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0539219S378819-20.225968455854.428.11.75bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 8 of 10

DIME Test ID: 2019-09-20-6-8
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0539219S378820-20.225943654432.726.31.74bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 9 of 10

DIME Test ID: 2019-09-20-6-9
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597719S378821-20.2185976957571.340.21.89bewing
UTM 120kip
Temperature 72 f
Extensometers no data

Test 10 of 10

DIME Test ID: 2019-09-20-6-10
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/27/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597719S378821-50.2185953956677.430.61.73bewing
UTM 120kip
Temperature 72 f
Extensometers no data