Print Report | Back to Sample Detail

Sample Record for 2019-09-06-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-09-06-10
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Retest
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/06/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/09/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: A449 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s):
Heat Number(s): 3087319
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A449
Bolt Length(s): 30
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: .875
Bolt Mfg. Lot Number: 56048-1
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 2

DIME Test ID: 2019-09-06-10-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 09/12/2019
Date Tested: 09/12/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Head Popped Off
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1UNC 7/8 0.462647766477514020713706063321Head Popped Off
UTM 400kip
Temperature 72

Test 2 of 2

DIME Test ID: 2019-09-06-10-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 09/12/2019
Date Tested: 09/12/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Head Popped Off
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
2UNC 7/8 0.462673966739514587913757663560Head Popped Off
UTM 400kip
Temperature 72