Print Report | Back to Test Summary

Testing Report for 2019-08-08-8-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project
EFIS:
Project ID: 0
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-08-08-8
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/8/2019
Date that the sample was received by the laboratory/organization performing the testing: 8/14/2019
The quantity of what the sample constitutes: 9
A brief description of the sample: 1-1/2"" x 5-1/2" HS Bolt Assys
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS Lindon UT

Material Information

Rocap Number(s): TT0031885
Heat Number(s): 62134200 M669280 235580
Nut Mfg. Lot Number(s): TL481
Washer Mfg. Lot Number(s): C7027M
Bolt Specification: ASTM A325
Bolt Length(s): 5-1/2"
Nut Specification: ASTM A563 Grade DH
Washer Specification: ASTM F436
Finish: Mechanically Galvanized
Diameter/Size: 1-1/2"
Bolt Mfg. Lot Number: 037492
Rocap Test Requirement(s): Test 2 Samples
Lubricant Requirements(s): NA

Test Information

DIME Test ID: 2019-08-08-8-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Date Tested: 8/27/2019
Verified Date: 8/30/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 037492
Finish Coating: ASTM B695 - Mech Galv
Product Markings: SL A325 B
Size: 1.5 in
Bolt Length: 5.5 in
Measurement Average: 8.71 mils