Print Report | Back to Test Summary

Testing Report for 2019-08-06-4-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 044G8404
EFIS: 0413000051
Project ID: 212244
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-128-20.1/20.4
Work Description: REPLACE CAPELL CREEK BRIDGE
Location Description: NAPA COUNTY ABOUT 15 MILES EAST OF RUTHERFORD FROM 1.1 MILES EAST OF KNOXVILLE ROAD TO 0.3 MILE WEST OF CAPELL VALLEY CREST
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Darren Isada
Structure Rep.: Nana Budu

Sample Information

DIME Sample ID: 2019-08-06-4
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 8/6/2019
Date that the sample was received by the laboratory/organization performing the testing: 8/9/2019
The quantity of what the sample constitutes: 60
A brief description of the sample: #18 Bar Splice Coupler
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Camblin Steel Service

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau CMC
Coupler Manufacturer: Bar Splice
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 18
Coupler Model: BarGrip XL
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): A183663
Rebar Heat Number(s): 9000571, 9000568
Rebar Size 2 : 18

Test Information

DIME Test ID: 2019-08-06-4-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 8/16/2019
Verified Date: 8/16/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 1 No. 18/57mm 4 0 387306 96827 OK Necking fsaylor
Temperature: 72.00 f
UTM: 2000kip
Halo ID: