Print Report | Back to Sample Detail

Sample Record for 2019-07-18-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-07-18-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/18/2019
Date that the sample was received by the laboratory/organization performing the testing: 07/25/2019
The quantity of what the sample constitutes: 3,000
A brief description of the sample: 1/2" DIRECT TENSION INDICATOR F959
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s):
Heat Number(s): 11802330
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s): 123C3
Bolt Specification: N/A
Bolt Length(s):
Nut Specification: N/A
Washer Specification: F959
Finish: MECHANICALLY GALVANIZED
Diameter/Size: 1/2"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 5

DIME Test ID: 2019-07-18-6-1
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/14/2019
Date Tested: 08/13/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 123C3
Finish Coating ASTM B695 - Mech Galv
Product Markings 325 C3
Size .5 in
Bolt Length no data in
Measurement Average 3.06 mils

Test 2 of 5

DIME Test ID: 2019-07-18-6-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/14/2019
Date Tested: 08/13/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 123C3
Finish Coating ASTM B695 - Mech Galv
Product Markings 325 C3
Size .5 in
Bolt Length no data in
Measurement Average 2.57 mils

Test 3 of 5

DIME Test ID: 2019-07-18-6-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/14/2019
Date Tested: 08/13/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 123C3
Finish Coating ASTM B695 - Mech Galv
Product Markings 325 C3
Size .5 in
Bolt Length no data in
Measurement Average 4.32 mils

Test 4 of 5

DIME Test ID: 2019-07-18-6-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/14/2019
Date Tested: 08/13/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 123C3
Finish Coating ASTM B695 - Mech Galv
Product Markings 325 C3
Size .5 in
Bolt Length no data in
Measurement Average 5.63 mils

Test 5 of 5

DIME Test ID: 2019-07-18-6-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/14/2019
Date Tested: 08/13/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 123C3
Finish Coating ASTM B695 - Mech Galv
Product Markings 325 C3
Size .5 in
Bolt Length no data in
Measurement Average 4.48 mils