Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213963 DEA: 024H1404 EFIS: 0218000072
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-36-6.6
Work Description: REPLACE SALT/SAND STORAGE BUILDING.
Location Description: PLUMAS COUNTY NEAR CHESTER AT THE CHESTER MAINTENANCE STATION
Contractor Name: Plummberbuilt Construction Inc.
Contractor Address: Po Box 474, Herald, CA 95638
Resident Engineer: John Yolton Structure Rep.: Jeff Rothgery
DIME Sample ID: 2019-07-09-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 07/09/2019
Date that the sample was received by the laboratory/organization performing the testing: 07/11/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: Epoxy Coated Rebar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coating
Rebar Heat Number(s): 6503078402
Rebar Epoxy Batch Number(s):
Rebar Coating Specification: ASTM A775
Rebar Size (#): 6
Rebar Coating Color: Green
Rebar Manufacturer: Gerdau
Rebar Coater: Western Coating
Rebar Powder Manufacturer: Unknown
Release Number: Unknown
Quality Assurance Code: Unknown
DIME Test ID: 2019-07-09-8-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 07/22/2019
Date Tested: 07/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
8.36
|
Second Bar Mean
|
8.48
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
16
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
8.42
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-07-09-8-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 07/22/2019
Date Tested: 07/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|