Print Report | Back to Sample Detail

Sample Record for 2019-06-28-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-06-28-7
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 06/28/2019
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2019
The quantity of what the sample constitutes: 9
A brief description of the sample: Wire Rope
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Oakland Paint Dept

Material Information

Reel Number: Unknown
Painter Name or ID: S143219 S146803 S146080 S145020 S145243 S146551 S145125 S146552 S145603
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer: Unknown
Material Collected to Test: Operator

Test Results

Test 1 of 9

DIME Test ID: 2019-06-28-7-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10526 lbf
Operator Lauren Coray-Sivil
Location of Failure Broke near crimp

Test 2 of 9

DIME Test ID: 2019-06-28-7-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10422 lbf
Operator Jesse Saylor
Location of Failure Broke near crimp

Test 3 of 9

DIME Test ID: 2019-06-28-7-3
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10513 lbf
Operator Ckemonte Lyons
Location of Failure Broke near crimp

Test 4 of 9

DIME Test ID: 2019-06-28-7-4
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10547 lbf
Operator Sherri Kid
Location of Failure Broke near crimp

Test 5 of 9

DIME Test ID: 2019-06-28-7-5
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10380 lbf
Operator Majesty Edwards
Location of Failure Broke near crimp

Test 6 of 9

DIME Test ID: 2019-06-28-7-6
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10422 lbf
Operator Ahmed Yusaf
Location of Failure Broke near crimp

Test 7 of 9

DIME Test ID: 2019-06-28-7-7
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10494 lbf
Operator Melanie Deborba
Location of Failure Broke near crimp

Test 8 of 9

DIME Test ID: 2019-06-28-7-8
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10472 lbf
Operator Angelo Ramirez
Location of Failure Broke near crimp

Test 9 of 9

DIME Test ID: 2019-06-28-7-9
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 07/12/2019
Date Tested: 07/09/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10300 lbf
Operator Arriama Payne
Location of Failure Broke near crimp