Print Report | Back to Test Summary

Testing Report for 2019-06-19-20-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080Q75U4
EFIS: 0817000114
Project ID: 213746
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Work Description: REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ashraf Mohamed
Structure Rep.: Ching Chuang

Sample Information

DIME Sample ID: 2019-06-19-20
TL Number from the TL Form: 8619
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 6/19/2019
Date that the sample was received by the laboratory/organization performing the testing: 6/20/2019
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: Soil Sample Native Selected
From where was the sample collected: Source
Laboratory sample identification: 8619
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Caltrans

Material Information

The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: A-19-005
Where the material sample would have been placed if not sampled: Unknown

Test Information

DIME Test ID: 2019-06-19-20-4
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Date Tested: 6/24/2019
Verified Date: 7/3/2019
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 98 %
Cumulative percent passing the 3/8 in. sieve: 97 %
Cumulative percent passing the #4 sieve: 93 %
Cumulative percent passing the #8 sieve: 81 %
Cumulative percent passing the #16 sieve: 66 %
Cumulative percent passing the #30 sieve: 47 %
Cumulative percent passing the #50 sieve: 28 %
Cumulative percent passing the #100 sieve: 16 %
Cumulative percent passing the #200 sieve: 10 %