Print Report | Back to Test Summary

Testing Report for 2019-06-18-10-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 083555V4
EFIS: 0814000086
Project ID: 210569
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-42.5/46.0
Work Description: WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location Description: SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Taghreed Al-Khateeb
Structure Rep.: Ravinder Singh

Sample Information

DIME Sample ID: 2019-06-18-10
TL Number from the TL Form: 20190618
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 6/18/2019
Date that the sample was received by the laboratory/organization performing the testing: 6/26/2019
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 934-0618
Structure unique identifier:
Structure name: MOJAVE RIVER BRIDGE LEFT
The fabricator/manufacturer/facility name: na

Material Information

The concrete mix design number: SITI72A
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: MOJAVE RIVER BRIDGE LEFT
Where the material sample would have been placed if not sampled: MOJAVE RIVER BRIDGE LEFT
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2019-06-18-10-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 6/28/2019
Capped in accordance with: ASTM C617/CTM521
Verified Date: 7/1/2019
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Capped in accordance with?: ASTM C617/CTM521
Compressive strength (to nearest 10 psi): 4510 psi
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Compressive strength of cylinder 1: 4471.5 psi
Compressive strength of cylinder 2: 4547.1 psi
Maximum load on cylinder 1: 126410 lb
Maximum load on cylinder 2: 129000 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 10 days