Testing Report for 2019-05-21-1-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07121844
EFIS: 0700000117
Project ID: 3807
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-42.8/47.3
Work Description: CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: James Shih
Structure Rep.: Matthew Remo

Sample Information

DIME Sample ID: 2019-05-21-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 5/21/2019
Date that the sample was received by the laboratory/organization performing the testing: 5/21/2019
The quantity of what the sample constitutes: 51
A brief description of the sample: A325 HDG Rocap Assembiy
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Industrial Bolt and Supply

Material Information

Rocap Number(s): 8756A325-1G, 8760A325-1G, 8764A325-1G, 8772A325-1G, 8776A325-1G and 8788A325-1G
Heat Number(s): 100792152, 100885411, 100887131, NF16200513, NF12204477 and NF14101299
Nut Mfg. Lot Number(s): 388511A
Washer Mfg. Lot Number(s): 312019
Bolt Specification: A325
Bolt Length(s): 3-3/4, 4", 4-1/2, 5-1/2, 4-3/4, and 3-1/2
Nut Specification: A194-2H
Washer Specification: F436
Finish: Hot Dipped Galvanized
Diameter/Size: 7/8
Bolt Mfg. Lot Number: 406901A, 388325A, 402256A, 370768A, 322090A a
Rocap Test Requirement(s):
Lubricant Requirements(s): Dye coated

Test Information

DIME Test ID: 2019-05-21-1-7
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Date Tested: 6/3/2019
Verified Date: 6/4/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Bolt Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Wedge Angle (deg) Comments Tested By
6A 351206A 7/8\" 67918 302.1 10 A325 Steve
UTM: 400KIP
Temperature: no data