Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-04-24-32
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/24/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2019
The quantity of what the sample constitutes: 36
A brief description of the sample: A325 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KT Bolt
Rocap Number(s):
Heat Number(s): 3083242
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325 HDG
Bolt Length(s): 4.5" 4.0" 3.5"
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 1.5"
Bolt Mfg. Lot Number: 54265-1 54177-1 54177-2
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2019-04-24-32-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 05/24/2019
Date Tested: 05/21/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | 54265-1 | 1.5\" | 186832 | 831.1 | 6 | A325 | Steve |
| |
UTM
|
400KIP
|
Temperature
|
no data
|
DIME Test ID: 2019-04-24-32-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 05/24/2019
Date Tested: 05/21/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1B | 54265-1 | 1.5\" | 188068 | 836.6 | 6 | A325 | Steve |
| |
UTM
|
400KIP
|
Temperature
|
no data
|
DIME Test ID: 2019-04-24-32-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Pitch Diameter
|
1.406 in
|
Pitch Diameter 2nd
|
1.406 in
|
DIME Test ID: 2019-04-24-32-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Pitch Diameter
|
1.403 in
|
Pitch Diameter 2nd
|
1.403 in
|
DIME Test ID: 2019-04-24-32-5
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Pitch Diameter
|
1.403 in
|
Pitch Diameter 2nd
|
1.403 in
|
DIME Test ID: 2019-04-24-32-6
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Pitch Diameter
|
1.402 in
|
Pitch Diameter 2nd
|
1.402 in
|
DIME Test ID: 2019-04-24-32-7
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Pitch Diameter
|
1.402 in
|
Pitch Diameter 2nd
|
1.402 in
|
DIME Test ID: 2019-04-24-32-8
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Pitch Diameter
|
1.409 in
|
Pitch Diameter 2nd
|
1.409 in
|
DIME Test ID: 2019-04-24-32-9
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Pitch Diameter
|
1.416 in
|
Pitch Diameter 2nd
|
1.416 in
|
DIME Test ID: 2019-04-24-32-10
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Pitch Diameter
|
1.413 in
|
Pitch Diameter 2nd
|
1.413 in
|
DIME Test ID: 2019-04-24-32-11
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Pitch Diameter
|
1.410 in
|
Pitch Diameter 2nd
|
1.410 in
|
DIME Test ID: 2019-04-24-32-12
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Pitch Diameter
|
1.412 in
|
Pitch Diameter 2nd
|
1.412 in
|
DIME Test ID: 2019-04-24-32-13
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
1.411 in
|
Pitch Diameter 2nd
|
1.411 in
|
DIME Test ID: 2019-04-24-32-14
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
1.403 in
|
Pitch Diameter 2nd
|
1.403 in
|
DIME Test ID: 2019-04-24-32-15
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
1.399 in
|
Pitch Diameter 2nd
|
1.399 in
|
DIME Test ID: 2019-04-24-32-16
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
1.410 in
|
Pitch Diameter 2nd
|
1.410 in
|
DIME Test ID: 2019-04-24-32-17
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
1.412 in
|
Pitch Diameter 2nd
|
1.412 in
|
DIME Test ID: 2019-04-24-32-18
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
2.45 mils
|
DIME Test ID: 2019-04-24-32-19
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
3.29 mils
|
DIME Test ID: 2019-04-24-32-20
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
2.99 mils
|
DIME Test ID: 2019-04-24-32-21
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
4.38 mils
|
DIME Test ID: 2019-04-24-32-22
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54265-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
3.19 mils
|
DIME Test ID: 2019-04-24-32-23
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
3.57 mils
|
DIME Test ID: 2019-04-24-32-24
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
6.08 mils
|
DIME Test ID: 2019-04-24-32-25
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
5.69 mils
|
DIME Test ID: 2019-04-24-32-26
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
2.96 mils
|
DIME Test ID: 2019-04-24-32-27
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
2.5 mils
|
DIME Test ID: 2019-04-24-32-28
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
3.56 mils
|
DIME Test ID: 2019-04-24-32-29
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
2.77 mils
|
DIME Test ID: 2019-04-24-32-30
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
2.43 mils
|
DIME Test ID: 2019-04-24-32-31
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
2.97 mils
|
DIME Test ID: 2019-04-24-32-32
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
2.93 mils
|
DIME Test ID: 2019-04-24-32-33
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
23.64
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-34
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
27
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-35
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.05
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-36
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
24.17
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-37
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
23.2
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-38
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
25.25
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-39
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
22.35
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-40
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
21.87
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-41
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
22.62
|
Spacing
|
Ok
|
DIME Test ID: 2019-04-24-32-42
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
54177-2
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A325
|
Size
|
1.5 in
|
Bolt Length
|
3.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
22.02
|
Spacing
|