Print Report | Back to Sample Detail

Sample Record for 2019-05-10-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-R5.6/7.6
Work Description: WEST SPAN DAMPER BRACKET A325 BOLT TESTING
Location Description: SFOBB WEST SPAN
Contractor Name: CALIFORNIA ENGINEERING CONTRACTORS, INC.
Contractor Address: 20 Happy Valley Road, Pleasanton, CA 94566
Resident Engineer: Tom Larwin Structure Rep.: Sergio Gomez

Sample Information

DIME Sample ID: 2019-05-10-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/10/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/15/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: A354 BC ATR
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Atlanta Rod

Material Information

Rocap Number(s):
Heat Number(s): 62147385
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A354 BC
Bolt Length(s): 12.5"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 1.25"
Bolt Mfg. Lot Number: 69857-003
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 6

DIME Test ID: 2019-05-10-17-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1621473850.5050.213490914931018.1Steve
UTM 67KIP
Temperature 72 f

Test 2 of 6

DIME Test ID: 2019-05-10-17-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
2621473850.5040.213436114889017.3Steve
UTM 67KIP
Temperature 72 f

Test 3 of 6

DIME Test ID: 2019-05-10-17-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 62147385
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings ATLROD BC
Size 1.25 in
Bolt Length 12.5 in
Pitch Diameter 1.178 in
Pitch Diameter 2nd 1.178 in

Test 4 of 6

DIME Test ID: 2019-05-10-17-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 62147385
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings ATLROD BC
Size 1.25 in
Bolt Length 12.5 in
Pitch Diameter 1.173 in
Pitch Diameter 2nd 1.173 in

Test 5 of 6

DIME Test ID: 2019-05-10-17-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 62147385
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings ATLROD BC
Size 1.25 in
Bolt Length 12.5 in
Measurement Average 8.52 mils

Test 6 of 6

DIME Test ID: 2019-05-10-17-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 62147385
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings ATLROD BC
Size 1.25 in
Bolt Length 12.5 in
Measurement Average 8.95 mils