Testing Report for 2019-04-24-32-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-24-32
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 4/24/2019
Date that the sample was received by the laboratory/organization performing the testing: 5/14/2019
The quantity of what the sample constitutes: 36
A brief description of the sample: A325 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KT Bolt

Material Information

Rocap Number(s):
Heat Number(s): 3083242
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325 HDG
Bolt Length(s): 4.5" 4.0" 3.5"
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 1.5"
Bolt Mfg. Lot Number: 54265-1 54177-1 54177-2
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2019-04-24-32-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Date Tested: 5/21/2019
Verified Date: 5/24/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Bolt Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Wedge Angle (deg) Comments Tested By
1B 54265-1 1.5\" 188068 836.6 6 A325 Steve
UTM: 400KIP
Temperature: no data