Print Report | Back to Sample Detail

Sample Record for 2019-04-24-32

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-24-32
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/24/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2019
The quantity of what the sample constitutes: 36
A brief description of the sample: A325 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KT Bolt

Material Information

Rocap Number(s):
Heat Number(s): 3083242
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325 HDG
Bolt Length(s): 4.5" 4.0" 3.5"
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 1.5"
Bolt Mfg. Lot Number: 54265-1 54177-1 54177-2
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 42

DIME Test ID: 2019-04-24-32-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 05/24/2019
Date Tested: 05/21/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A54265-11.5\"186832831.16A325Steve
UTM 400KIP
Temperature no data

Test 2 of 42

DIME Test ID: 2019-04-24-32-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 05/24/2019
Date Tested: 05/21/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1B54265-11.5\"188068836.66A325Steve
UTM 400KIP
Temperature no data

Test 3 of 42

DIME Test ID: 2019-04-24-32-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Pitch Diameter 1.406 in
Pitch Diameter 2nd 1.406 in

Test 4 of 42

DIME Test ID: 2019-04-24-32-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Pitch Diameter 1.403 in
Pitch Diameter 2nd 1.403 in

Test 5 of 42

DIME Test ID: 2019-04-24-32-5
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Pitch Diameter 1.403 in
Pitch Diameter 2nd 1.403 in

Test 6 of 42

DIME Test ID: 2019-04-24-32-6
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Pitch Diameter 1.402 in
Pitch Diameter 2nd 1.402 in

Test 7 of 42

DIME Test ID: 2019-04-24-32-7
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Pitch Diameter 1.402 in
Pitch Diameter 2nd 1.402 in

Test 8 of 42

DIME Test ID: 2019-04-24-32-8
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Pitch Diameter 1.409 in
Pitch Diameter 2nd 1.409 in

Test 9 of 42

DIME Test ID: 2019-04-24-32-9
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Pitch Diameter 1.416 in
Pitch Diameter 2nd 1.416 in

Test 10 of 42

DIME Test ID: 2019-04-24-32-10
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Pitch Diameter 1.413 in
Pitch Diameter 2nd 1.413 in

Test 11 of 42

DIME Test ID: 2019-04-24-32-11
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Pitch Diameter 1.410 in
Pitch Diameter 2nd 1.410 in

Test 12 of 42

DIME Test ID: 2019-04-24-32-12
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Pitch Diameter 1.412 in
Pitch Diameter 2nd 1.412 in

Test 13 of 42

DIME Test ID: 2019-04-24-32-13
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Pitch Diameter 1.411 in
Pitch Diameter 2nd 1.411 in

Test 14 of 42

DIME Test ID: 2019-04-24-32-14
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Pitch Diameter 1.403 in
Pitch Diameter 2nd 1.403 in

Test 15 of 42

DIME Test ID: 2019-04-24-32-15
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Pitch Diameter 1.399 in
Pitch Diameter 2nd 1.399 in

Test 16 of 42

DIME Test ID: 2019-04-24-32-16
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Pitch Diameter 1.410 in
Pitch Diameter 2nd 1.410 in

Test 17 of 42

DIME Test ID: 2019-04-24-32-17
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Pitch Diameter 1.412 in
Pitch Diameter 2nd 1.412 in

Test 18 of 42

DIME Test ID: 2019-04-24-32-18
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Measurement Average 2.45 mils

Test 19 of 42

DIME Test ID: 2019-04-24-32-19
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Measurement Average 3.29 mils

Test 20 of 42

DIME Test ID: 2019-04-24-32-20
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Measurement Average 2.99 mils

Test 21 of 42

DIME Test ID: 2019-04-24-32-21
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Measurement Average 4.38 mils

Test 22 of 42

DIME Test ID: 2019-04-24-32-22
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54265-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4.5 in
Measurement Average 3.19 mils

Test 23 of 42

DIME Test ID: 2019-04-24-32-23
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Measurement Average 3.57 mils

Test 24 of 42

DIME Test ID: 2019-04-24-32-24
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Measurement Average 6.08 mils

Test 25 of 42

DIME Test ID: 2019-04-24-32-25
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Measurement Average 5.69 mils

Test 26 of 42

DIME Test ID: 2019-04-24-32-26
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Measurement Average 2.96 mils

Test 27 of 42

DIME Test ID: 2019-04-24-32-27
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Measurement Average 2.5 mils

Test 28 of 42

DIME Test ID: 2019-04-24-32-28
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Measurement Average 3.56 mils

Test 29 of 42

DIME Test ID: 2019-04-24-32-29
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Measurement Average 2.77 mils

Test 30 of 42

DIME Test ID: 2019-04-24-32-30
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Measurement Average 2.43 mils

Test 31 of 42

DIME Test ID: 2019-04-24-32-31
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Measurement Average 2.97 mils

Test 32 of 42

DIME Test ID: 2019-04-24-32-32
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Measurement Average 2.93 mils

Test 33 of 42

DIME Test ID: 2019-04-24-32-33
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Hardness Reading Scale C Scale
Hardness Reading Average 23.64
Spacing Ok

Test 34 of 42

DIME Test ID: 2019-04-24-32-34
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Hardness Reading Scale C Scale
Hardness Reading Average 27
Spacing Ok

Test 35 of 42

DIME Test ID: 2019-04-24-32-35
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Hardness Reading Scale C Scale
Hardness Reading Average 29.05
Spacing Ok

Test 36 of 42

DIME Test ID: 2019-04-24-32-36
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Hardness Reading Scale C Scale
Hardness Reading Average 24.17
Spacing Ok

Test 37 of 42

DIME Test ID: 2019-04-24-32-37
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 2E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 4 in
Hardness Reading Scale C Scale
Hardness Reading Average 23.2
Spacing Ok

Test 38 of 42

DIME Test ID: 2019-04-24-32-38
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Hardness Reading Scale C Scale
Hardness Reading Average 25.25
Spacing Ok

Test 39 of 42

DIME Test ID: 2019-04-24-32-39
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Hardness Reading Scale C Scale
Hardness Reading Average 22.35
Spacing Ok

Test 40 of 42

DIME Test ID: 2019-04-24-32-40
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Hardness Reading Scale C Scale
Hardness Reading Average 21.87
Spacing Ok

Test 41 of 42

DIME Test ID: 2019-04-24-32-41
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Hardness Reading Scale C Scale
Hardness Reading Average 22.62
Spacing Ok

Test 42 of 42

DIME Test ID: 2019-04-24-32-42
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 54177-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.5 in
Hardness Reading Scale C Scale
Hardness Reading Average 22.02
Spacing Ok