Print Report | Back to Test Summary

Testing Report for 2019-04-29-8-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07288604
EFIS: 0700021080
Project ID: 208945
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer:
Structure Rep.:

Sample Information

DIME Sample ID: 2019-04-29-8
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: 760-518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 4/29/2019
Date that the sample was received by the laboratory/organization performing the testing: 4/29/2019
The quantity of what the sample constitutes: 10 Tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik bond and Reichhold

Material Information

Mfg. Lot Number(s): 1181101
Batch number: 1181101
Mix number: 1181101

Test Information

DIME Test ID: 2019-04-29-8-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Date Tested: 5/20/2019
Verified Date: 5/20/2019
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test: accepted suppliers test results (685 psi )
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Curing history for Sample 1: 24hr
Maximum applied load (P) for Sample 1: 824 lb
Span length for Sample 1: 9 in
Break location for Sample 1: bond
Specimen defects/notes for Sample 1: no data
Surface type for Sample 1: SSD
Modulus of rupture (R) for Sample 1: 412 psi
Curing history for Sample 2: 24hr
Maximum applied load (P) for Sample 2: 973 lb
Span length for Sample 2: 9 in
Break location for Sample 2: bond
Specimen defects/notes for Sample 2: no data
Surface type for Sample 2: SSD
Modulus of rupture (R) for Sample 2: 486.5 psi
Curing history for Sample 3: 24hr
Maximum applied load (P) for Sample 3: 883 lb
Span length for Sample 3: 9 in
Break location for Sample 3: bond
Specimen defects/notes for Sample 3: no data
Surface type for Sample 3: SSD
Modulus of rupture (R) for Sample 3: 441.5 psi