Print Report | Back to Test Summary

Testing Report for 2019-05-08-13-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120H1004
EFIS: 1200000180
Project ID: 208973
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405,73,405,605-9.3/24.3
Work Description: (Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location Description: Orange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Hank Alonso (reports)
Structure Rep.: Cal Zachman (reports)

Sample Information

DIME Sample ID: 2019-05-08-13
TL Number from the TL Form: C926381
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 5/8/2019
Date that the sample was received by the laboratory/organization performing the testing: 5/9/2019
The quantity of what the sample constitutes: 500
A brief description of the sample: D101 and D101A Bar Splice
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dayton Superior

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Dayton Superior
Intermediate Assembler or Fabricator: Dayton Superior
Rebar Size: 6
Coupler Model: D101A
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): Ht 35400003924 / Lot 350000392420
Rebar Heat Number(s): 3500003960, 35400003924
Rebar Size 2 : 6

Test Information

DIME Test ID: 2019-05-08-13-9
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 5/15/2019
Verified Date: 5/16/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 3 #6/19mm 0.44 0 40081 91093 Service Splice Brian
Temperature: 72 F
UTM: 400KIP
Halo ID: Small