Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212304 DEA: 021C7504 EFIS: 0200000080
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-14.9
Work Description: CONCRETE BRIDGE, RETAINING WALLS, HMA, DRAINAGE AND GUARDRAIL.
Location Description: PLUMAS COUNTY NEAR BELDEN AT YELLOW CREEK BRIDGE 09-0008
Contractor Name: STEWART ENGINEERING INC
Contractor Address: PO Box 990010, Redding, CA 96099-0010
Resident Engineer: John Yolton Structure Rep.: Bryan Keene
DIME Sample ID: 2019-04-11-7
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 04/11/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/16/2019
The quantity of what the sample constitutes: 4
A brief description of the sample: Casting
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Farrar
Heat Number (s): A319 C209
Part Number (s): 68 04 2532 68 05 144
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): DSI
Prestressing Manufacturer: Farrar
DIME Test ID: 2019-04-11-7-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 04/19/2019
Date Tested: 04/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
4
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | A319 | 0.502 | 0.1979 | 61363 | 107240 | 10.9 | Steve | | A319 | 0.501 | 0.1971 | 61390 | 108020 | 10.8 | Steve | | C209 | 0.502 | 0.1979 | 63324 | 113180 | 9.1 | Steve | | C209 | 0.502 | 0.1979 | 62978 | 112920 | 9.5 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|