Print Report | Back to Test Summary

Testing Report for 2019-04-04-9-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 08347704
EFIS: 0800000616
Project ID: 209695
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-SR-58-0/12.9
Work Description: (Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location Description: SR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Shaine Shahidi
Structure Rep.: Osama Abdalla

Sample Information

DIME Sample ID: 2019-04-04-9
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 4/4/2019
Date that the sample was received by the laboratory/organization performing the testing: 4/5/2019
The quantity of what the sample constitutes: 8 Bags
A brief description of the sample: 1/2 HMA-A-SP
From where was the sample collected: Manufacturer
Laboratory sample identification: 0214A-19
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Company - Oro Grande

Material Information

Source Identification (SMARA or name of Pit): 91-36-0042::HI-GRADE MATERIALS COMPANY
The fabricator's/manufacturer's product name for the sample: 1/2 HMA-A-SP
The fabricator/manufacturer designation for the sample: 324109 SJR - ORO
The plant number: Unknown
A detailed description of where the material sample was collected: Manufacturer
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2019-04-04-9-9
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Date Tested: 4/10/2019
Verified Date: 4/23/2019
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: RAP Gradation After Ignition Oven
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 98 %
Cumulative percent passing the #4 sieve: 83 %
Cumulative percent passing the #8 sieve: 67 %
Cumulative percent passing the #16 sieve: 53 %
Cumulative percent passing the #30 sieve: 38 %
Cumulative percent passing the #50 sieve: 25 %
Cumulative percent passing the #100 sieve: 16 %
Cumulative percent passing the #200 sieve: 11.1 %