Print Report | Back to Test Summary

Testing Report for 2019-02-01-13-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 060H2004
EFIS: 0612000157
Project ID: 213583
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-201,216-12.5,21.2,18.7
Work Description: BRIDGE WIDENING, UPGRADE LANES AND OUTSIDE SHOULDERS.
Location Description: TULARE COUNTY NEAR CUTLER ON ROUTE 201 AT SAND CREEK BRIDGE AND AT FRIANT KERN CANAL BRIDGE AND NEAR WOODLAKE ON ROUTE 216 AT KAWEAH RIVER BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Donald Hiura
Structure Rep.: Peter Moua

Sample Information

DIME Sample ID: 2019-02-01-13
TL Number from the TL Form: C922805C
Sample Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Sample Organization Contact: (916) 227-7204
Type of Sample: Annual Source Testing
Type of Material: Aggregate
Sample Taken Date: 2/1/2019
Date that the sample was received by the laboratory/organization performing the testing: 3/1/2019
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: Coarse PCC Aggregate
From where was the sample collected: Source
Laboratory sample identification: 19-CPCC-0065
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Friant Fresno

Material Information

Source Identification (SMARA or name of Pit): 91-10-0014::ROCKFIELD PLANT
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Stockpile
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2019-02-01-13-1
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Date Tested: 4/16/2019
Verified Date: 4/16/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: bang.d.nguyen@dot.ca.gov
Organization Phone: (916) 227-7204
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 2.6 %