Print Report | Back to Test Summary

Testing Report for 2019-03-26-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project
EFIS:
Project ID: 0
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-03-26-2
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 3/26/2019
Date that the sample was received by the laboratory/organization performing the testing: 4/2/2019
The quantity of what the sample constitutes: 3 lots
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts and washers
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s):
Heat Number(s): 474118, 284732, 182292
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): 313770, 314963
Bolt Specification: F1554
Bolt Length(s): 10 1/2"
Nut Specification: N/A
Washer Specification: F436
Finish: HDG
Diameter/Size: 3/4", 2-1/4"
Bolt Mfg. Lot Number: 75C144THR55/M
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2019-03-26-2-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 4/10/2019
Verified Date: 4/26/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Gr55 AT
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1A F1554 Gr 55 AT 0.334 26498 117 79335 66835 22323 F1554 Gr55 AT
UTM: 400KIP
Temperature: 72