Print Report | Back to Test Summary

Testing Report for 2019-04-01-1-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 040J3804
EFIS: 0413000462
Project ID: 213723
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-680-R11.0/R12.0
Work Description: CONSTRUCT SOIL NAIL WALLS AND GEOSYNTHETIC REINFORCED EMBANKMENTS
Location Description: CONTRA COSTA COUNTY AT ALAMO FROM 0.3 MILE SOUGHT OF LIVORNA ROAD UNDERCROSSING TO 0.6 MILE SOUTH OF RUDGEAR ROAD UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Amir Hatefi
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-01-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 4/1/2019
Date that the sample was received by the laboratory/organization performing the testing: 4/3/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: #8 Threaded Bar with nuts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 8
Nut Specification for Threaded Bar: ASTM A519
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Soil Nail
Coating Standards: Uncoated
Bar Heat Number(s): 62148703 and 62149036
Nut Heat Number(s): 00A184094 and 00A164230
Bar Lot Number: N/A
Nut Lot Number: N/A
Coupler Heat Number(s): N/A
Coupler Grade: N/A

Test Information

DIME Test ID: 2019-04-01-1-3
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 4/5/2019
Verified Date: 4/9/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Mfg Lot Area (sqin) Tensile Strength (psi) Stress at Offset (psi) Total Elongation (%) Comments Tested By
3 #8 Bar Heat #62149036, Nut Heat 00A184094 NA 0.79 111899 76632 9.3 A615 Threaded Bar and Nut Brian
Temperature: 72 F
UTM: 400KIP