Print Report | Back to Test Summary

Testing Report for 2019-03-14-3-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 054482U4
EFIS: 0500000543
Project ID: 211235
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-2.2/3.3
Work Description: BUILD AND RECONSTRUCT BRIDGES, CONSTRUCT RAMPS AND FRONTAGE ROAD.
Location Description: SANTA BARBARA COUNTY IN CARPINTERIA FROM 0.2 MILE SOUTH OF CARPINTERIA CREEK BRIDGE TO FRANKLIN CREEK BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tristan Gebhart
Structure Rep.: Raymond Barajas

Sample Information

DIME Sample ID: 2019-03-14-3
TL Number from the TL Form:
Sample Submitted By Organization: Caltrans Vallejo Field Laboratory
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 3/14/2019
Date that the sample was received by the laboratory/organization performing the testing: 3/20/2019
The quantity of what the sample constitutes: 150
A brief description of the sample: Zap couplers
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bar Splice

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Zap
Intermediate Assembler or Fabricator: Harris Rebar
Rebar Size: 8
Coupler Model: Zap
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): MM18106565, MM18103576
Rebar Heat Number(s): 3500005186, 3500004803
Rebar Size 2 : 10

Test Information

DIME Test ID: 2019-03-14-3-6
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 3/22/2019
Verified Date: 3/22/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 C24 #10/32mm 1.27 0 122640 96565 Service Splice Fred
Temperature: 72 F
UTM: 400KIP
Halo ID: Larger