Sample Record for 2019-03-11-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-34.7/51.6
Work Description: (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location Description: Riverside County and SBD-15-0.0/1.3
Contractor Name: Skanska-Ames, Joint Venture
Contractor Address: 1801 California Avenue, Corona, CA 92881
Resident Engineer: Roy Fisher (reports) Structure Rep.: Roy Fisher
Sample Information
DIME Sample ID: 2019-03-11-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 03/11/2019
Date that the sample was received by the laboratory/organization performing the testing: 03/19/2019
The quantity of what the sample constitutes: 1 lot
A brief description of the sample: Epoxy Coated Dowel
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JC Supply and Manufacturing
Material Information
Dowel Metal Heat Number: SE18101988, 1202005040,
1201008153, 1202008018, 1202006692, 1201006754 1201009492, 1202009370
1202006692
Dowel Epoxy Batch Number: 8996028085 8V96028644
Dowel Coating Specification: ASTM A775
Dowel Size: 1.25 in
Dowel Coating Color: Green
Dowel Manufacturer:
Dowel Coater: JC Supply And Manufacturing
Release Number:
Quality Assurance Code:
Rebar Size (#):
Test Results
Test 1 of 2
DIME Test ID: 2019-03-11-3-1
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 03/20/2019
Date Tested: 03/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
11.68 mils
|
Second Bar Mean
|
12.33 mils
|
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
40 mils
|
Total mean value
|
12 mils
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
Test 2 of 2
DIME Test ID: 2019-03-11-3-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 03/20/2019
Date Tested: 03/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
1.5
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|