Print Report | Back to Sample Detail | Back to Aggregate Report

Sample Record for 2018-02-27-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-02-27-26
TL Number from the TL Form: 18-J-006
Sample Submitted By Organization: Sierra Pacific Materials
Sample Organization Contact: (805) 423-2327
Type of Sample: Quality Control
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 02/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/27/2018
The quantity of what the sample constitutes: JMF Renewal
A brief description of the sample: 1/2 HMA
From where was the sample collected: Manufacturer
Laboratory sample identification: 18-J-006
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPM-Templeton

Material Information

RAP Source: Stockpile
Aggregate Size: 1/2
Aggregate Source: Unknown
RAP Stockpile:
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2018-02-27-26-1
Test Method: CTM 202-Oct 2014: Method of Test for Determining Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 02/24/2019
Date Tested: 03/22/2018
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What size aggregate is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99.1 %
Cumulative percent passing the 3/8 in. sieve 92.8 %
Cumulative percent passing the #4 sieve 75.9 %
Cumulative percent passing the #8 sieve 62.3 %
Cumulative percent passing the #16 sieve 49.6 %
Cumulative percent passing the #30 sieve 36.2 %
Cumulative percent passing the #50 sieve 23.4 %
Cumulative percent passing the #100 sieve 14.1 %
Cumulative percent passing the #200 sieve 9.5 %

Test 2 of 3

DIME Test ID: 2018-02-27-26-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/24/2019
Date Tested: 03/22/2018
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.80 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 3 of 3

DIME Test ID: 2018-02-27-26-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 02/24/2019
Date Tested: 03/22/2018
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.483
Theoretical maximum density at 25°C (77°F) no data