Print Report | Back to Sample Detail

Sample Record for 2019-02-13-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: YYZ
Contractor Address: 1234 address, Sacramento, CA 95824
Resident Engineer: RE_first RE_last Structure Rep.: SR_First SR_Last

Sample Information

DIME Sample ID: 2019-02-13-1
TL Number from the TL Form: Test
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 02/13/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/13/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: Test
From where was the sample collected: Source
Laboratory sample identification: Test
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Test

Material Information

Source Identification (SMARA, name of Pit or Job Site): Test
The fabricator's/manufacturer's product name for the sample: Test
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Test
A detailed description of where the material sample was collected: Test
Where the material sample would have been placed if not sampled: Test
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: 1
Sublot number: 1
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2019-02-13-1-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 02/13/2019
Date Tested: 02/13/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 200 %
Cumulative percent passing the 3/4 in. sieve 88 %
Cumulative percent passing the 1/2 in. sieve 31 %
Cumulative percent passing the 3/8 in. sieve 3 %
Cumulative percent passing the 1/4 in. sieve 3 %
Cumulative percent passing the #4 sieve 1 %
Cumulative percent passing the #8 sieve 1 %
Cumulative percent passing the #16 sieve 0.5 %
Cumulative percent passing the #30 sieve 0 %
Cumulative percent passing the #50 sieve 0 %
Cumulative percent passing the #100 sieve 0 %
Cumulative percent passing the #200 sieve 0 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2019-02-13-1-2AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)02/13/201902/13/2019Clinton EdmistonCT HQ - Sacramento Hot Mix Asphalt Laboratory
2019-02-13-1-3AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)02/13/201902/13/2019Clinton EdmistonCT HQ - Sacramento Hot Mix Asphalt Laboratory
2019-02-13-1-4AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)02/13/201902/13/2019Clinton EdmistonCT HQ - Sacramento Hot Mix Asphalt Laboratory
2019-02-13-1-6AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)02/13/201902/13/2019Clinton EdmistonCT HQ - Sacramento Hot Mix Asphalt Laboratory
2019-02-13-1-7AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)02/13/201902/13/2019Clinton EdmistonCT HQ - Sacramento Hot Mix Asphalt Laboratory