Print Report | Back to Test Summary

Testing Report for 2014-04-18-12006226-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 112T1824
EFIS: 1100020051
Project ID: 7780
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tom Davis
Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2014-04-18-12006226
TL Number from the TL Form:
Sample Submitted By Organization: RMA Group - Rancho Cucamonga
Sample Organization Contact: 909-989-1751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 4/18/2014
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 5 cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification: 2014-04-18-1200
Structure unique identifier: 2014-04-18-1200
Structure name:
The fabricator/manufacturer/facility name: Vulcan Mission Valley

Material Information

The concrete mix design number: 103612F
The truck number from where the sample was collected: 328
The batch plant ticket number from where the sample was collected: 110684
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW 316R Wall Station 16 plus 50 to 17 plus 00
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2014-04-18-12006226-6
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 5/2/2014
Capped in accordance with: ASTM C617/CTM521
Verified Date: 6/20/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email:
Organization Phone: 619-572-9564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Compressive strength of cylinder (to nearest 10 psi): 3120 psi
Average diameter of cylinder 1: 6.00 in
Maximum load on cylinder 1: 88270 lb
Type of fracture pattern of cylinder 1: 6
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 14 days