Print Report | Back to Test Summary

Testing Report for 2018-12-28-9-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-12-28-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/28/2018
Date that the sample was received by the laboratory/organization performing the testing: 1/16/2019
The quantity of what the sample constitutes: 5
A brief description of the sample: A325 Fastener Assembly
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor unytite

Material Information

Rocap Number(s):
Heat Number(s): DL17101703, 6214745502, 188269
Nut Mfg. Lot Number(s): 29394-S-6214745502
Washer Mfg. Lot Number(s): 310064
Bolt Specification: A325 HDG
Bolt Length(s): 5"
Nut Specification: A563 HDG
Washer Specification: F436 HDG
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number: 39336A
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2018-12-28-9-4
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 1/17/2019
Verified Date: 1/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: nut proof
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1B 29394-6214745502 1\" 93156 414.38 nut proof Steve
UTM: 400KIP
Temperature: 72 F