Print Report | Back to Test Summary

Testing Report for 2018-11-15-7-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 044G8504
EFIS: 0413000052
Project ID: 212376
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-1-R44.1
Work Description: REPLACE PEDESTRIAN OVERCROSSING
Location Description: SAN MATEO COUNTY IN PACIFICA AT THE SAN JOSE AVENUE PEDESTRIAN OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Jose Mario David
Structure Rep.: Jason Louie

Sample Information

DIME Sample ID: 2018-11-15-7
TL Number from the TL Form: C794242
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 11/15/2018
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: Couplers
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau, HRC

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau
Coupler Manufacturer: HRC
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 11
Coupler Model: 500 510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): 8293932, 100890383
Rebar Heat Number(s): 65032549 02
Rebar Size 2 :

Test Information

DIME Test ID: 2018-11-15-7-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 11/16/2018
Verified Date: 11/16/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
1 1 #11/36mm 1.56 -0.0056 143250 91828 Service Splice Brian
Temperature: 72 F
UTM: 400KIP
Halo ID: Small