Print Report | Back to Sample Detail

Sample Record for 2018-10-30-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213203 DEA: 010H9804 EFIS: 0118000138 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-162-16.08
Work Description: Construct Soldier Pile Ground Anchor Wall
Location Description:
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: 200 Dinsmore Dr., Fortuna, CA 95540
Resident Engineer: Nash Munes Structure Rep.: Brian Cinkutis

Sample Information

DIME Sample ID: 2018-10-30-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/30/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/31/2018
The quantity of what the sample constitutes: 3
A brief description of the sample: 5/8 x 9 A449 HDG all thread rod
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s): none
Heat Number(s): DL15101249
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): n/a
Bolt Specification: A449 HDG
Bolt Length(s): 9"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG
Diameter/Size: 5/8" x 9"
Bolt Mfg. Lot Number: 29328
Rocap Test Requirement(s): none
Lubricant Requirements(s): none

Test Results

Test 1 of 7

DIME Test ID: 2018-10-30-1-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 All Thread Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1AA449 All Thread Rod0.2263074013613601812195127561A449 All Thread Rod
UTM 400KIP
Temperature 72

Test 2 of 7

DIME Test ID: 2018-10-30-1-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) DL15101249
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings A449 01AE
Size .625 in
Bolt Length 9 in
Gage Type Pass

Test 3 of 7

DIME Test ID: 2018-10-30-1-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) DL15101249
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings A449 01AE
Size .625 in
Bolt Length 9 in
Gage Type Pass

Test 4 of 7

DIME Test ID: 2018-10-30-1-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) DL15101249
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings A449 01AE
Size .625 in
Bolt Length 9 in
Gage Type Pass

Test 5 of 7

DIME Test ID: 2018-10-30-1-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) DL15101249
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings A449 01AE
Size .625 in
Bolt Length 9 in
Measurement Average 4.57 mils

Test 6 of 7

DIME Test ID: 2018-10-30-1-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) DL15101249
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings A449 01AE
Size .625 in
Bolt Length 9 in
Measurement Average 4.18 mils

Test 7 of 7

DIME Test ID: 2018-10-30-1-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/13/2018
Date Tested: 11/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) DL15101249
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings A449 01AE
Size .625 in
Bolt Length 9 in
Measurement Average 3.64 mils