Project ID: 212577 DEA: 11408704 EFIS: 1112000017
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-9.0/15.3
Work Description: SLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL.
Location Description: SAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON
Contractor Name: FLATIRON WEST, INC.
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: John Williamson Structure Rep.: Unknown
DIME Sample ID: 2018-10-01-12
TL Number from the TL Form: na
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Acceptance
Type of Material: Cementitious
Sample Taken Date: 10/01/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2018
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Rapid Setting Cement
From where was the sample collected: Job Site
Laboratory sample identification: CM184801
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMAX
DIME Test ID: 2018-10-01-12-1
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/14/2019
Date Tested: 10/18/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 day break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
3003 psi
|
Compressive strength of 2nd specimen (psi)
|
3262 psi
|
Compressive strength of 3rd specimen (psi)
|
3352 psi
|
Average Compressive strength (to nearest 10 psi)
|
3210 psi
|
DIME Test ID: 2018-10-01-12-2
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Verified Date: 01/14/2019
Date Tested: 10/29/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Specimen A Initial measurement at 24 hours
|
0.2648 in
|
Specimen B Initial measurement at 24 hours
|
0.2536 in
|
Specimen C Initial measurement at 24 hours
|
0.3069 in
|
Specimen D Initial measurement at 24 hours
|
0.2542 in
|
Specimen A Final measurement at 14 days
|
0.2654 in
|
Specimen B Final measurement at 14 days
|
0.2541 in
|
Specimen C Final measurement at 14 days
|
0.3074 in
|
Specimen D Final measurement at 14 days
|
0.2546 in
|
The average length of change of the four specimens
|
0.050 %
|
DIME Test ID: 2018-10-01-12-3
Test Method: CTM 527-February 2014: Method of Test for Expansion in Water and Contraction in Air of Portland Cement Mortar
Verified Date: 01/14/2019
Date Tested: 10/19/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Average change in length in water
|
50.12 %
|
Average change in length in air
|
49.50 %
|
DIME Test ID: 2018-10-01-12-4
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Verified Date: 01/14/2019
Date Tested: 10/19/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h
|
17850 kPa
|
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h
|
25250 kPa
|
Thermal stability ratio
|
141
|