Print Report | Back to Test Summary

Testing Report for 2018-10-12-13-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-10-12-13
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/12/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/23/2018
The quantity of what the sample constitutes: 12
A brief description of the sample: A325 TC Bolt assys
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tru-fit Products

Material Information

Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): 26975-177742, 399097B, 406668C, 406668A
Washer Mfg. Lot Number(s): D3888, 031905, 032502, 032338
Bolt Specification: A325 TC
Bolt Length(s): 1.75, 1.75, 2, 2.25
Nut Specification: A563
Washer Specification: F436
Finish: Plain
Diameter/Size: .625, .75
Bolt Mfg. Lot Number: 26986-10498480, 400776B, 407384E, 405337B
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2018-10-12-13-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 10/24/2018
Verified Date: 10/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1A 26975-177742 5/8-11 Hex 39853 177.28 Nut Proof Load Brian
UTM: 400KIP
Temperature: 72 F