Print Report | Back to Test Summary

Testing Report for 2018-10-05-12-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 051J6304
EFIS: 0518000006
Project ID: 213093
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-0.0/13.5
Work Description: Remove slide material, repair or replace damaged highway facilities
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tristan Gebhart
Structure Rep.: Ray Barajas

Sample Information

DIME Sample ID: 2018-10-05-12
TL Number from the TL Form: C761565
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 10/5/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2018
The quantity of what the sample constitutes: Unknown
A brief description of the sample: Standard Barlock Coupler
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dayton Superior

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau
Coupler Manufacturer: Dayton Superior
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 6
Coupler Model: Barlock
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): MM16106573 MM16106574 MM17105957
Rebar Heat Number(s): 6503123902
Rebar Size 2 :

Test Information

DIME Test ID: 2018-10-05-12-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 10/17/2018
Verified Date: 10/17/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 1 #6/19mm 0.44 0 42388 96336 Service Splice Fred
Temperature: 72 F
UTM: 400KIP
Halo ID: Small