Print Report | Back to Sample Detail

Sample Record for 2018-09-24-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211775 DEA: 024E6504 EFIS: 0212000012 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-96-R52.5/88.4
Work Description: WIDEN BRIDGES,POLYESTER CONC OVERLAY,COLD PLANE AC PVMT,HMA,GUARDRAIL
Location Description: SISKIYOU COUNTY NEAR SEIAD VALLEY AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF THOMPSON CREEK BRIDGE TO 0.2 MILE EAST OF BEAVER CREEK BRIDGE
Contractor Name: J.F. Shea Construction, Inc
Contractor Address: 17400 Clearcreek Road, Redding, CA 96001
Resident Engineer: Mark Loader Structure Rep.: Robert Thompson

Sample Information

DIME Sample ID: 2018-09-24-8
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 09/24/2018
Date that the sample was received by the laboratory/organization performing the testing: 09/28/2018
The quantity of what the sample constitutes: 3
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DS Brown Seismic Energy

Material Information

Mfg. Lot Number(s): 54726-1A1, 5E1, 6F1
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 13.5" x 9" x 1.75"
Comments: Unknown
Description (Number of Shims): 3
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): DS Brown
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2018-09-24-8-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 10/19/2018
Date Tested: 10/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 54
Reading #2 53
Reading #3 54
Reading #4 55
Reading #5 54
Mean 54

Test 2 of 4

DIME Test ID: 2018-09-24-8-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 10/19/2018
Date Tested: 10/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.075 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2925.5 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.069 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2774.6 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.076 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2421.1 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2774.6 lbf/in^2

Test 3 of 4

DIME Test ID: 2018-09-24-8-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 10/19/2018
Date Tested: 10/04/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.062 in
Sample 1 Tear Strength 274.2 lbf / in
Sample 2 Median Thickness 0.071 in
Sample 2 Tear Strength 295.8 lbf / in
Sample 3 Median Thickness 0.07 in
Sample 3 Tear Strength 285.7 lbf / in
Median of the Tear Strength Values 285.7 lb/in

Test 4 of 4

DIME Test ID: 2018-09-24-8-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 10/04/2018
Date Tested: 10/04/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass