Print Report | Back to Test Summary

Testing Report for 2018-08-29-12-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 032F5904
EFIS: 0300020624
Project ID: 213152
QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB,NEV-20-20.1/21.7, 0.0/0.1
Work Description: CURVE REALIGNMENT AND SHOULDER WIDENING
Location Description: YUBA AND NEVADA COUNTIES NEAR SMARTSVILLE FROM 0.5 MILE WEST OF MCGANNEY LANE TO MOONEY FLAT ROAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Aaron Chamberlin
Structure Rep.: Justin Wood

Sample Information

DIME Sample ID: 2018-08-29-12
TL Number from the TL Form: C874432
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 8/29/2018
Date that the sample was received by the laboratory/organization performing the testing: 9/7/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rebar Tracy

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 4073439
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 7
Diameter of Hoop: 4'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: CMC Rebar
Welding Company: CMC Rebar (Tracy)
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2018-08-29-12-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 9/10/2018
Verified Date: 9/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
1 1 #7/22mm 0.6 59410 99020 Bar Broke Brian
UTM: 400KIP
Temperature: 72 F