Print Report | Back to Test Summary

Testing Report for 2018-08-24-3-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07288604
EFIS: 0700021080
Project ID: 208945
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer:
Structure Rep.:

Sample Information

DIME Sample ID: 2018-08-24-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/24/2018
Date that the sample was received by the laboratory/organization performing the testing: 8/24/2018
The quantity of what the sample constitutes: 20
A brief description of the sample: 1 inch A325 Bolts
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerald Desmond Bridge

Material Information

Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): 28125-6214552205 / 28125-6214435405 / TN731 /
Washer Mfg. Lot Number(s): D4996Z / D4996
Bolt Specification: A325
Bolt Length(s): 3", 4", 5", 5-1/2, 6", 3-3/4, 7", 8", and 8-1
Nut Specification: A563-DH
Washer Specification: F436
Finish: Galvanized
Diameter/Size: 1"
Bolt Mfg. Lot Number: 28054-10537450 / 28065-10541510 / 28058-10541
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2018-08-24-3-4
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 9/4/2018
Verified Date: 9/11/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
7A TN731 1\" 93871 417.56 Proof Load Fred
UTM: 400KIP
Temperature: 72 F